search results

  1. AC switchgear // IP65, SPD AC Noark type 2, off overcurrent EM-470N_AC

    Constructed to ensure robust protection and control for AC power circuits, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a Surge Protection Device (SPD) of Noark type 2, which is engineered to safeguard electrical equipment from voltage spikes.<br><br>The switchgear features an off overcurrent capability of 50A across three phases, providing a safeguard against excessive current that could cause damage to cables or equipment. Additionally, it includes a Residual Current Device (RCD) of type A with a rated sensitivity of 63A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating direct currents, thereby preventing electric shock and fire hazards caused by earth faults.<br><br>The unit is identified by the emiter code EM-470N_AC, which signifies its specific model and technical specifications. This switchgear is suitable for a variety of applications where electrical safety and equipment protection are paramount. Its robust construction and safety features make it a valuable component in electrical installations requiring precise circuit control and protection....

    Senetic IE

  2. AC switchgear // IP65, SPD AC Dehn type 2, off overcurrent EM-470_AC

    Constructed to ensure robust protection for AC power distribution systems, the unit features an ingress protection rating of IP65, signifying its dust-tight design and resistance to low-pressure water jets from any direction. This level of protection makes it suitable for challenging environments where exposure to particulate matter and moisture is a concern.<br><br>Equipped with a Surge Protection Device (SPD) of AC Dehn type 2, the device is designed to safeguard electrical equipment from voltage spikes, providing an additional layer of security against power surges that can result from lightning strikes or switching operations.<br><br>The switchgear includes an overcurrent protection feature rated at 50A for three-phase applications, ensuring that the system is safeguarded against excessive currents which could potentially cause damage to the circuit or connected devices.<br><br>Additionally, it incorporates a Residual Current Device (RCD) of type A with a rating of 63A/300mA. This component is critical for detecting and interrupting circuit imbalances that may indicate leakage currents, which could pose a risk of electric shock or fire.<br><br>The model EM-470_AC is engineered to deliver enhanced safety and stability for electrical installations, making it a suitable choice for a wide range of industrial and commercial applications....

    Senetic IE

  3. DCAC switchgear // IP65, SPD DC Dehn 1000V type 2, 2 x PV EM-528_DCAC

    Engineered to ensure seamless energy management and distribution, the EM-528_DCAC switchgear is a robust solution designed to cater to advanced electrical infrastructure needs. Enclosed within an IP65-rated casing, this switchgear offers a high degree of protection against dust and water ingress, making it suitable for challenging environmental conditions.<br><br>The unit comes equipped with a DC surge protection device (SPD) from Dehn, rated at 1000V type 2, which is adept at safeguarding the system from transient overvoltage. It supports two photovoltaic (PV) strings and is compatible with two maximum power point tracking (MPPT) inputs, enhancing the efficiency of solar energy systems.<br><br>On the alternating current (AC) side, the switchgear features an AC SPD, also from Dehn, classified as type 2. This component is essential for protecting electrical equipment from surge events on the AC network. The switchgear includes a 16A 3-phase circuit breaker, ensuring safe and controlled distribution of electricity.<br><br>Additionally, it incorporates a residual current device (RCD) type A with a rating of 40A/300mA. This safety device is designed to interrupt the circuit if it detects a potentially dangerous imbalance between the incoming and outgoing current, thereby providing protection against electric shock and reducing the risk of electrical fires.<br><br>Overall, this switchgear is engineered to offer enhanced safety and efficiency for electrical systems requiring robust energy management solutions....

    Senetic IE

  4. AC switchgear // IP65, SPD AC Noark type 1+2, off EM-357N_AC

    Constructed to ensure robust protection and control for AC power circuits, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a surge protection device (SPD) of Noark type 1+2, offering defense against transient overvoltages and ensuring the safety of electrical equipment.<br><br>The switchgear features an off overcurrent capability of 32A across a three-phase system (3-F), effectively safeguarding circuits from excessive current that could cause damage or pose a fire risk. Additionally, it is equipped with a residual current device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating DC fault currents, thereby minimizing the risk of electric shock and preventing electrical fire hazards.<br><br>The product is identified by the emiter code EM-357N_AC, which is unique to this specific model of switchgear, ensuring easy identification and reference for installation and maintenance purposes. Its robust construction and integrated protective features make it suitable for a wide range of industrial and commercial electrical applications....

    Senetic IE

  5. AC switchgear // IP65, SPD AC Noark type 2, off overcurrent EM-296N_AC

    Constructed to ensure robust protection and control for AC power circuits, the unit features an ingress protection rating of IP65, signifying its dust-tight design and resistance to low-pressure water jets from any direction. This characteristic makes it suitable for use in environments where exposure to particulate matter and moisture is a concern.<br><br>Equipped with a surge protection device (SPD) of Noark type 2, the switchgear is designed to safeguard electrical equipment from transient overvoltage events, thereby extending the lifespan of connected devices and reducing the risk of damage due to power surges.<br><br>The switchgear is capable of interrupting overcurrents up to 10A in three-phase (3-F) systems, providing essential protection against excessive current flow that could potentially cause overheating or fires.<br><br>Additionally, it incorporates a residual current device (RCD) of type A with a rated sensitivity of 40A/300mA. This component is crucial for preventing electric shock and fire hazards by detecting and interrupting circuit imbalances that may not be apparent but pose serious safety risks.<br><br>The model EM-296N_AC from Emitter underscores a commitment to electrical safety and system integrity in demanding applications....

    Senetic IE

  6. AC switchgear // IP65, SPD AC Noark type 2, off overcurrent EM-299N_AC

    Constructed to ensure robust protection and control for AC power circuits, the unit features an ingress protection rating of IP65, signifying its dust-tight design and resistance to water jets from any direction. This level of protection ensures that the internal components remain safeguarded against environmental factors, making it suitable for a wide range of demanding applications.<br><br>The switchgear is equipped with a surge protection device (SPD) of Noark type 2, designed to shield electrical equipment from voltage spikes. This SPD is specifically engineered to handle transient overvoltage, thereby contributing to the longevity and safety of connected devices.<br><br>For current regulation, the switchgear includes an off overcurrent feature rated at 32A for three-phase systems. This function is essential for preventing damage to the system caused by excessive current flow.<br><br>Additionally, the unit incorporates a residual current device (RCD) of type A with a rating of 40A/300mA. This RCD is sensitive to pulsating DC fault currents, providing an extra layer of safety by detecting and interrupting circuit imbalances that could lead to electric shock or fire hazards.<br><br>The model EM-299N_AC from Emitter underscores a commitment to electrical safety and system integrity....

    Senetic IE

  7. AC switchgear // IP65, SPD AC Noark type 1+2, off EM-307N_AC

    Constructed to ensure robust protection and control for AC power circuits, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a surge protection device (SPD) of Noark type 1+2, offering defense against transient overvoltages and ensuring the safety of electrical equipment.<br><br>The switchgear features an off overcurrent capability of 20A across three phases, providing a safeguard against excessive current that could potentially cause damage or pose a fire risk. Additionally, it includes a residual current device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is adept at detecting AC sinusoidal waveforms as well as pulsating DC earth leakage currents, thereby enhancing the protection against electric shock and preventing electrical fire hazards.<br><br>The unit is identified by the model em-307n_ac, which signifies its specific configuration and capabilities within the emiter product range. Its construction and features are tailored to ensure consistent performance in various industrial and commercial settings where electrical safety and circuit integrity are paramount....

    Senetic IE

  8. AC switchgear // IP65, SPD AC Dehn type 2, off overcurrent EM-296_AC

    Crafted to ensure safety and efficiency in electrical circuits, this AC switchgear is designed with robust features to cater to a variety of applications. The unit boasts an ingress protection rating of IP65, signifying a high level of protection against dust ingress and low-pressure water jets from any direction, making it suitable for challenging environmental conditions.<br><br>Equipped with a Surge Protection Device (SPD) of Dehn type 2, the switchgear provides effective defense against transient overvoltages, thereby safeguarding connected electrical equipment from the potential damages caused by power surges. The off overcurrent protection is rated at 10A for three-phase (3-F) systems, ensuring that the circuit is promptly disconnected in the event of excessive current flow to prevent overheating and potential hazards.<br><br>Additionally, the inclusion of a Residual Current Device (RCD) of type A with a rating of 40A/300mA offers added security by detecting and interrupting earth fault currents, reducing the risk of electric shock and fire caused by ground faults. The product is identified by the emitter code EM-296_AC, which is associated with its specific model and technical specifications....

    Senetic IE

  1. Previous Page (Page 7)Next Page (Page 9)