search results

  1. DCAC switchgear // IP65, SPD DC Dehn 1000V type 2, 2 x PV EM-528_DCAC

    Engineered to ensure seamless energy management and distribution, the EM-528_DCAC switchgear is a robust solution designed to cater to advanced electrical infrastructure needs. Enclosed within an IP65-rated casing, this switchgear offers a high degree of protection against dust and water ingress, making it suitable for challenging environmental conditions.<br><br>The unit comes equipped with a DC surge protection device (SPD) from Dehn, rated at 1000V type 2, which is adept at safeguarding the system from transient overvoltage. It supports two photovoltaic (PV) strings and is compatible with two maximum power point tracking (MPPT) inputs, enhancing the efficiency of solar energy systems.<br><br>On the alternating current (AC) side, the switchgear features an AC SPD, also from Dehn, classified as type 2. This component is essential for protecting electrical equipment from surge events on the AC network. The switchgear includes a 16A 3-phase circuit breaker, ensuring safe and controlled distribution of electricity.<br><br>Additionally, it incorporates a residual current device (RCD) type A with a rating of 40A/300mA. This safety device is designed to interrupt the circuit if it detects a potentially dangerous imbalance between the incoming and outgoing current, thereby providing protection against electric shock and reducing the risk of electrical fires.<br><br>Overall, this switchgear is engineered to offer enhanced safety and efficiency for electrical systems requiring robust energy management solutions....

    Senetic IE

  2. AC switchgear // IP65, SPD AC Noark type 2, off overcurrent EM-453N_AC

    Crafted to ensure safety and efficiency in electrical circuits, the emiter em-453n_ac is a robust AC switchgear that meets the stringent IP65 rating, signifying its dust-tight construction and protection against water jets from any direction. This switchgear is equipped with a Surge Protection Device (SPD) of Noark type 2, designed to shield electrical equipment from voltage spikes.<br><br>The unit features an off overcurrent capability of 40A in a 3-phase configuration, providing a safeguard against excessive current that could potentially cause damage to the circuit or connected devices. Additionally, it incorporates a Residual Current Device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is sensitive to pulsating direct current which could be indicative of a fault in the electrical installation, offering an extra layer of protection against electric shock and fire hazards.<br><br>The em-453n_ac switchgear is engineered for durability and consistent performance, making it suitable for a variety of applications where electrical safety is paramount. Its design adheres to established standards, ensuring compatibility and ease of integration into electrical systems....

    Senetic IE

  3. AC switchgear // IP65, SPD AC Noark type 2, off overcurrent EM-470N_AC

    Constructed to ensure robust protection and control for AC power circuits, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a Surge Protection Device (SPD) of Noark type 2, which is engineered to safeguard electrical equipment from voltage spikes.<br><br>The switchgear features an off overcurrent capability of 50A across three phases, providing a safeguard against excessive current that could cause damage to cables or equipment. Additionally, it includes a Residual Current Device (RCD) of type A with a rated sensitivity of 63A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating direct currents, thereby preventing electric shock and fire hazards caused by earth faults.<br><br>The unit is identified by the emiter code EM-470N_AC, which signifies its specific model and technical specifications. This switchgear is suitable for a variety of applications where electrical safety and equipment protection are paramount. Its robust construction and safety features make it a valuable component in electrical installations requiring precise circuit control and protection....

    Senetic IE

  4. DCAC switchgear // IP65, SPD DC Noark 1000V type 2, 1 x PV EM-41N_DCAC

    Constructed to ensure robust protection and control for photovoltaic systems, this switchgear is designed to cater to the needs of a single PV string with one MPPT. It features an IP65-rated enclosure, signifying a high level of protection against dust ingress and low-pressure water jets from any direction, making it suitable for various environmental conditions.<br><br>The unit includes a DC surge protection device (SPD) from Noark rated at 1000V, type 2, which is engineered to safeguard the electrical equipment from transient over-voltage events, thereby enhancing the longevity and safety of the connected systems. Additionally, an AC SPD, also from Noark and classified as type 2, is integrated into the system to provide similar protection on the AC side.<br><br>With a 20A 3-phase configuration, the switchgear is capable of handling significant current loads, ensuring compatibility with a wide range of applications. The inclusion of the emiter EM-41N_DCAC signifies a commitment to quality and durability, offering users a dependable solution for their energy management and protection requirements....

    Senetic IE

  5. AC switchgear // IP65, SPD AC Noark type 1+2, off EM-446N_AC

    Constructed to ensure robust protection for AC power systems, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a Surge Protection Device (SPD) of Noark type 1+2, engineered to safeguard electrical equipment from voltage spikes.<br><br>The switchgear features an off overcurrent capability of 10A across a three-phase (3-F) system, providing a safeguard against excessive current that could cause damage to circuits or pose a fire risk. Additionally, it is equipped with a Residual Current Device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating DC earth leakage currents, thereby offering enhanced protection against electric shock and electrical fire hazards.<br><br>The unit is identified by the model number EM-446N_AC, which is associated with the brand Emitter. This model is engineered to deliver consistent performance in a variety of settings where electrical safety and equipment protection are paramount. Its robust construction and integrated protective features make it suitable for applications requiring stringent safety measures and operational durability....

    Senetic IE

  6. AC switchgear // IP65, SPD AC Noark type 1+2, off EM-316N_AC

    Crafted to ensure safety and efficiency in electrical circuits, the unit features an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. This high level of protection makes it suitable for use in environments where exposure to dust and moisture is a concern.<br><br>Equipped with a Surge Protection Device (SPD) of Noark type 1+2, the switchgear provides robust defense against transient overvoltage, safeguarding electrical equipment from lightning strikes and power surges. The off overcurrent capability is rated at 50A for 3-phase systems, ensuring the switchgear can handle high current scenarios without compromise.<br><br>Additionally, the inclusion of a Residual Current Device (RCD) of type A with a rating of 63A/300mA offers protection against earth fault currents, reducing the risk of electric shock and fire caused by ground faults. The EM-316N_AC model is designed to deliver a combination of protection features that contribute to the safe operation of electrical installations....

    Senetic IE

  7. AC switchgear // IP65, SPD AC Noark type 1+2, off EM-357N_AC

    Constructed to ensure robust protection and control for AC power circuits, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a surge protection device (SPD) of Noark type 1+2, offering defense against transient overvoltages and ensuring the safety of electrical equipment.<br><br>The switchgear features an off overcurrent capability of 32A across a three-phase system (3-F), effectively safeguarding circuits from excessive current that could cause damage or pose a fire risk. Additionally, it is equipped with a residual current device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating DC fault currents, thereby minimizing the risk of electric shock and preventing electrical fire hazards.<br><br>The product is identified by the emiter code EM-357N_AC, which is unique to this specific model of switchgear, ensuring easy identification and reference for installation and maintenance purposes. Its robust construction and integrated protective features make it suitable for a wide range of industrial and commercial electrical applications....

    Senetic IE

  8. DCAC switchgear // IP65, SPD DC Dehn 1000V type 2, 2 x PV EM-382_DCAC

    Engineered to ensure the safe and efficient management of direct current (DC) and alternating current (AC) power in solar photovoltaic (PV) systems, this switchgear is a robust solution for energy conversion and circuit protection. It features an ingress protection rating of IP65, signifying a dust-tight enclosure with protection against water jets, making it suitable for challenging environmental conditions.<br><br>The unit includes a surge protection device (SPD) for DC applications, a Dehn 1000V type 2, designed to safeguard electrical equipment from voltage spikes. It supports two PV strings and is compatible with two maximum power point tracking (MPPT) controllers, enhancing the energy harvesting efficiency of solar installations.<br><br>Additionally, the switchgear is equipped with an AC Dehn type 2 SPD, providing similar surge protection for AC circuits. It is rated for 25A in a 3-phase configuration and includes a residual current device (RCD) type A with a 40A current rating and a 100mA trip sensitivity, offering critical protection against earth leakage currents.<br><br>The emiter, em-382_dcac, is built to maintain system integrity and protect against electrical anomalies, contributing to the longevity and safety of solar PV installations....

    Senetic IE

  1. Previous Page (Page 93)Next Page (Page 95)