Engineered to ensure seamless energy management and distribution, the EM-528_DCAC switchgear is a robust solution designed to cater to advanced electrical infrastructure needs. Enclosed within an IP65-rated casing, this switchgear offers a high degree of protection against dust and water ingress, making it suitable for challenging environmental conditions.<br><br>The unit comes equipped with a DC surge protection device (SPD) from Dehn, rated at 1000V type 2, which is adept at safeguarding the system from transient overvoltage. It supports two photovoltaic (PV) strings and is compatible with two maximum power point tracking (MPPT) inputs, enhancing the efficiency of solar energy systems.<br><br>On the alternating current (AC) side, the switchgear features an AC SPD, also from Dehn, classified as type 2. This component is essential for protecting electrical equipment from surge events on the AC network. The switchgear includes a 16A 3-phase circuit breaker, ensuring safe and controlled distribution of electricity.<br><br>Additionally, it incorporates a residual current device (RCD) type A with a rating of 40A/300mA. This safety device is designed to interrupt the circuit if it detects a potentially dangerous imbalance between the incoming and outgoing current, thereby providing protection against electric shock and reducing the risk of electrical fires.<br><br>Overall, this switchgear is engineered to offer enhanced safety and efficiency for electrical systems requiring robust energy management solutions....
Senetic IE
Constructed to ensure robust electrical circuit protection and management, the unit features an IP65-rated enclosure, providing a high level of protection against dust ingress and water jets from any direction. It is equipped with a Noark 1000V type 2 Surge Protection Device (SPD) on the DC side, designed to safeguard against transient overvoltage, which is essential for systems exposed to lightning strikes or power surges.<br><br>The switchgear accommodates two photovoltaic (PV) strings and is compatible with two Maximum Power Point Tracking (MPPT) inputs, enhancing the efficiency of solar energy systems by optimizing the power output from PV panels. On the alternating current (AC) side, it includes a Noark type 2 SPD, which similarly protects AC circuits from surge events.<br><br>Additionally, the switchgear is fitted with a 20A 3-phase circuit breaker that allows for safe and controlled distribution of electrical power across three-phase electrical systems. It also incorporates a Residual Current Device (RCD) type A with a 40A/300mA rating, which monitors for any imbalance between live conductors and instantly breaks the circuit in the event of earth leakage, thereby preventing electric shock hazards and fire risks.<br><br>The emiter EM-588N_DCAC model ensures enhanced safety and operational efficiency for electrical installations requiring stringent protection measures....
Senetic IE
Constructed to ensure robust protection for AC power systems, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a Surge Protection Device (SPD) of Noark type 1+2, engineered to safeguard electrical equipment from voltage spikes.<br><br>The switchgear features an off overcurrent capability of 10A across a three-phase (3-F) system, providing a safeguard against excessive current that could cause damage to circuits or pose a fire risk. Additionally, it is equipped with a Residual Current Device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating DC earth leakage currents, thereby offering enhanced protection against electric shock and electrical fire hazards.<br><br>The unit is identified by the model number EM-446N_AC, which is associated with the brand Emitter. This model is engineered to deliver consistent performance in a variety of settings where electrical safety and equipment protection are paramount. Its robust construction and integrated protective features make it suitable for applications requiring stringent safety measures and operational durability....
Senetic IE
Crafted to ensure safety and efficiency in electrical circuits, the unit features an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. This high level of protection makes it suitable for use in environments where exposure to dust and moisture is a concern.<br><br>Equipped with a Surge Protection Device (SPD) of Noark type 1+2, the switchgear provides robust defense against transient overvoltage, safeguarding electrical equipment from lightning strikes and power surges. The off overcurrent capability is rated at 50A for 3-phase systems, ensuring the switchgear can handle high current scenarios without compromise.<br><br>Additionally, the inclusion of a Residual Current Device (RCD) of type A with a rating of 63A/300mA offers protection against earth fault currents, reducing the risk of electric shock and fire caused by ground faults. The EM-316N_AC model is designed to deliver a combination of protection features that contribute to the safe operation of electrical installations....
Senetic IE
Constructed to ensure robust protection and control for AC power circuits, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a surge protection device (SPD) of Noark type 1+2, offering defense against transient overvoltages and ensuring the safety of electrical equipment.<br><br>The switchgear features an off overcurrent capability of 32A across a three-phase system (3-F), effectively safeguarding circuits from excessive current that could cause damage or pose a fire risk. Additionally, it is equipped with a residual current device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating DC fault currents, thereby minimizing the risk of electric shock and preventing electrical fire hazards.<br><br>The product is identified by the emiter code EM-357N_AC, which is unique to this specific model of switchgear, ensuring easy identification and reference for installation and maintenance purposes. Its robust construction and integrated protective features make it suitable for a wide range of industrial and commercial electrical applications....
Senetic IE
Crafted to ensure safety and efficiency in electrical circuits, the emiter em-265n_ac is a robust AC switchgear that offers comprehensive protection for a variety of applications. Enclosed in an IP65-rated casing, this switchgear is designed to prevent the ingress of dust and protect against low-pressure water jets from any direction, making it suitable for challenging environmental conditions.<br><br>The unit includes a Surge Protection Device (SPD) of Noark type 2, which is engineered to safeguard electrical equipment from voltage spikes. Its off overcurrent protection is rated at 20A for single-phase applications, ensuring that the circuit is promptly disconnected in the event of excessive current flow to prevent damage to the system.<br><br>Additionally, the switchgear features a Residual Current Device (RCD) of type A with a rated residual operating current of 300mA and a rated current of 40A. This RCD is sensitive to pulsating DC fault currents, providing an extra layer of safety against electric shock and fire hazards caused by earth faults.<br><br>The em-265n_ac switchgear is designed for seamless integration into electrical systems requiring dependable circuit protection and is suitable for both commercial and residential installations....
Senetic IE
Constructed to ensure robust protection for AC power circuits, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a Surge Protection Device (SPD) of Dehn type 2, offering safeguarding against transient overvoltages and ensuring the longevity of connected electrical systems.<br><br>The switchgear features an off overcurrent capability of 20A in a single-phase (1-F) configuration, providing a secure mechanism to interrupt current flow in the event of an overload or short circuit, thereby protecting the circuitry from damage. Additionally, it is equipped with a Residual Current Device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating DC earth leakage currents, enhancing the safety of the installation by reducing the risk of electric shock and fire caused by earth faults.<br><br>The unit is identified by the emiter code EM-265_AC, which is indicative of its specifications and manufacturer's product line. Its robust construction and integrated protective features make it suitable for a wide range of applications where electrical safety and equipment integrity are paramount....
Senetic IE
Constructed to ensure robust protection for AC power distribution systems, this switchgear is designed with an ingress protection rating of IP65, signifying its dust-tight construction and resistance to water jets from any direction. It incorporates a surge protection device (SPD) of AC Dehn type 2, which is engineered to safeguard electrical equipment from voltage spikes, thereby extending the lifespan of connected devices.<br><br>The switchgear features an off overcurrent capability of 16A for three-phase (3-F) systems, providing a safeguard against excessive current that could cause damage to the circuit or connected equipment. Additionally, it is equipped with a residual current device (RCD) of type A with a rated sensitivity of 40A/300mA. This RCD is specifically designed to detect and interrupt AC sinusoidal waveforms and pulsating DC fault currents, offering enhanced protection against electric shock and fire hazards caused by earth faults.<br><br>The unit is identified by the emiter code EM-268_AC, which is indicative of its specifications and manufacturer's product line. This switchgear is suitable for a variety of applications where safety and durability are paramount....
Senetic IE